Home Page | Company Profile | Hi-Z in the News | Technical Papers | Products | Online Store | Links | Contact Us     
 

HZ-20 Thermoelectric Module

Uses Bismuth Telluride Based Semiconductors
Solid State Conversion of Heat To Electricity


Generate a highly reliable source of electrical power from any source of heat. For these and other applications:

POWER SUPPLIES

SELF POWERED DEVICES

WASTE HEAT RECOVERY

RENEWABLE ENERGY

THE HZ-20 THERMOELECTRIC MODULE

The HZ-20 module consists of 71 thermocouples arranged electrically in series and thermally in parallel. The thermocouples consists of "Hot Pressed", Bismuth Telluride based, semiconductors to give the highest efficiency at most waste heat temperatures as well as high strength capable of enduring rugged applications. The bonded metal conductors enable the HZ-20 module to operate continuously at temperatures as high as 250°C (480 F) and intermittently as high as 400°C (750 F) without degrading the module.

While the HZ-20 is well suited for waste heat recovery it's reversible properties make it ideal as a thermoelectric cooler, especially for high temperature applications where sensitive electronic equipment must be cooled to below the ambient temperatures.

Properties of the 13 Watt Module, HZ-20
Physical Properties
Value
Tolerance
Width & Length
2.95" (7.5 cm)
±0.01 (0.25)
Thickness
(Special Order)
0.2" (0.508)
±0.01 (0.25)
±0.002 (0.05)
Weight
115 grams
±3 grams
Compressive Yield Stress
10 ksi (70 MPa)
minimum
Number of active couples
71 couples
----
Thermal Properties


Design Hot Side Temperature
230°C (450°F)
±10 (20)
Design Cold Side Temperature
30°C (85°F)
±5 (10)
Maximum Continuous Temperature
250°C (480°F)
----
Minimum Continuous Temperature
none
----
Maximum Intermittent Temperature
400°C (750°F)
----
Thermal Conductivity*
0.024 W/cm*K
+0.001
Heat Flux*
9.54 W/sqcm
±0.5
Electrical Properties (as a generator)*


Power**
19 Watts
minimum
Load Voltage
2.38 Volts
±0.1
Internal Resistance
0.3 Ohm
±0.05
Current
8 Amps
±1
Open Circuit Voltage
5.0 Volts
±0.3
Efficiency
4.5 %
minimum

* At Design Temperatures
** At Matched Load, refer to the graphs for properties at various operating temperatures and conditions.

Data Sheet

Module properties can be calculated at any temperature using our performance calculator:

Performance Calculator

AVAILABLE OPTIONS:


All statements, technical information and recommendations contained herein are based on tests we believe to be reliable, but the accuracy or completeness thereof is not guaranteed. Neither seller nor manufacturer shall be liable for any injury, loss or damage including but not limited to special, incidental or consequential damages arising out of the use or the inability to use the product. Before using, user shall determine the suitability of the product for his intended use, and user assumes all risk and liability whatsoever in connection therewith. No statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and manufacturer.